Dimensional diagram of EDR-75W guide rail series products | ||||
EDR-75W | ||||
EDR-75W Guide Rail Series Product Parameter Table | ||||
model | EDR-75 | |||
output | DC Voltage | 12V | 24V | 48V |
Rated current | 6.3A | 3.2A | 1.6A | |
rated power | 75W | 75W | 75W | |
Ripple and noise ① | 80mVp-p | 120mVp-p | 150mVp-p | |
Voltage regulation range | ±10% | |||
Voltage accuracy | ±2.0% | ±1.0% | ||
Line Regulation | <±0.5% | |||
Load Regulation | <±1.5% | <±0.5% | <±0.5% | |
input | Voltage range/frequency | 85-264VAC 47Hz-63Hz(120VDC-370VDC) | ||
Efficiency (typical) ② | >85% | >87% | >88% | |
Working current | <1.45A/115VAC <0.91A/230VAC | |||
Impulse current | 115VAC 25A,220VAC 50A | |||
Start, rise, hold time | 200ms、50ms、20ms :220VAC | |||
Protective characteristics | overload protection | ≥ 105% -150% Type: Constant current output+VO drops to undervoltage point Cut off output reset: Power on again | ||
Short circuit protection | +Vo drops to undervoltage point and closes output | |||
environment | Working temperature and humidity | -10℃~+50℃;20%~90RH | ||
Storage temperature and humidity | -20℃~+85℃;10%-95RH | |||
pressurization | Input output: 1.5KVAC Input housing: 1.5KVAC Output Housing: 0.5KVAC for 1 minute |
|||
Leakage current | <5mA at 1.5KVAC input output | |||
Leakage current | <1mA when input-output 220VAC | |||
Isolation resistor | Input output, input housing, output housing: 500VDC/100M Ω | |||
other | size | 32*125*102mm | ||
notes | ① Ripple and noise measurement method: Use a 12 “twisted pair cable, with terminals connected in parallel with 0.1uF and 47uF capacitors, and measure at a bandwidth of 20MHz. ② Efficiency is tested at an input voltage of 230VAC, rated load, and an ambient temperature of 25 ℃. Accuracy: including setting error, linear adjustment rate, and load adjustment rate. Linear adjustment rate testing method: Test from low voltage to high voltage under rated load Load adjustment rate testing method: from 0% to 100% of rated load. The startup time is measured in a cold start state, and rapid and frequent shutdowns may increase the startup time, When the operating altitude is above 2000 meters, the operating environment temperature needs to be reduced by 5 ℃/1000 meters |
Dimensional diagram of EDR-120W guide rail series products | ||||
EDR-120W | ||||
EDR-120W Guide Rail Series Product Parameter Table | ||||
model | EDR-120 | |||
output | DC Voltage | 12V | 24V | 48V |
Rated current | 10A | 5A | 2.5A | |
rated power | 120W | 120W | 120W | |
Ripple and noise ① | 100mVp-p | 120mVp-p | 150mVp-p | |
Voltage regulation range | ±10% | |||
Voltage accuracy | ±2.0% | ±1.0% | ||
Line Regulation | <±0.5% | |||
Load Regulation | <±1.5% | <±0.5% | <±0.5% | |
input | Voltage range/frequency | 85-264VAC 47Hz-63Hz(120VDC-370VDC) | ||
Efficiency (typical) ② | >85% | >87% | >88% | |
Working current | <12A 115VAC <7.8A 230VAC | |||
Impulse current | 115VAC 25A,220VAC 50A | |||
Start, rise, hold time | 200ms、50ms、20ms :220VAC | |||
Protective characteristics | overload protection | ≥ 105% -150% Type: Constant current output+VO drops to undervoltage point Cut off output reset: Power on again | ||
Short circuit protection | +Vo drops to undervoltage point and closes output | |||
environment | Working temperature and humidity | -10℃~+50℃;20%~90RH | ||
Storage temperature and humidity | -20℃~+85℃;10%-95RH | |||
pressurization | Input output: 1.5KVAC Input housing: 1.5KVAC Output Housing: 0.5KVAC for 1 minute |
|||
Leakage current | <5mA at 1.5KVAC input output | |||
Leakage current | <1mA when input-output 220VAC | |||
Isolation resistor | Input output, input housing, output housing: 500VDC/100M Ω | |||
other | size | 40*113.5*125mm | ||
notes | ① Ripple and noise measurement method: Use a 12 “twisted pair cable, with terminals connected in parallel with 0.1uF and 47uF capacitors, and measure at a bandwidth of 20MHz. ② Efficiency is tested at an input voltage of 230VAC, rated load, and an ambient temperature of 25 ℃. Accuracy: including setting error, linear adjustment rate, and load adjustment rate. Linear adjustment rate testing method: Test from low voltage to high voltage under rated load Load adjustment rate testing method: from 0% to 100% of rated load. The startup time is measured in a cold start state, and rapid and frequent shutdowns may increase the startup time, When the operating altitude is above 2000 meters, the operating environment temperature needs to be reduced by 5 ℃/1000 meters |
Dimensional diagram of EDR-150W guide rail series products | |||
EDR-150W | |||
EDR-150W Guide Rail Series Product Parameter Table | |||
model | EDR-150 | ||
output | DC Voltage | 24V | 48V |
Rated current | 6.25A | 3.2A | |
rated power | 150W | 150W | |
Ripple and noise ① | 150mVp-p | 150mVp-p | |
Voltage accuracy | ±10% | ||
Line Regulation | ±1.0% | ||
Load Regulation | ±1.0% | ||
Voltage adjustable range | ±10% | ||
input | Voltage range/frequency | 90-264VAC (127VDC-370VDC)/47Hz-63Hz | |
Efficiency (Typical) (Typ.) ② | 85.50% | 90% | |
AC current (Typ.) | 2.6A 115VAC 1.7A /230VAC | ||
Start, rise, hold time | 1500ms、60ms/230VAC,3000ms、60ms/115VAC | ||
Protective characteristics | overload protection | ≥ 105% -150% Type: Constant current output+VO drops to undervoltage point Cut off output reset: Power on again | |
Short circuit protection | +VO drops to undervoltage point and closes output | ||
environment | Working temperature and humidity | -10℃~+50℃;20%~90RH | |
Storage temperature and humidity | -20℃~+85℃;10%-95RH | ||
pressurization | Input output: 1.5KVAC Input housing: 1.5KVAC Output Housing: 0.5KVAC for 1 minute |
||
Leakage current | <5mA at 1.5KVAC input output | ||
Leakage current | <1mA when input-output 220VAC | ||
Isolation resistor | Input output, input housing, output housing: 500VDC/100M Ω | ||
size | 40*113.5*125mm | ||
notes | ① Ripple and noise measurement method: Use a 12 “twisted pair cable, with terminals connected in parallel with 0.1uF and 47uF capacitors, and measure at a bandwidth of 20MHz. ② Efficiency is tested at an input voltage of 230VAC, rated load, and an ambient temperature of 25 ℃. Accuracy: including setting error, linear adjustment rate, and load adjustment rate. Linear adjustment rate testing method: Test from low voltage to high voltage under rated load Load adjustment rate testing method: from 0% to 100% of rated load. The startup time is measured in a cold start state, and rapid and frequent shutdowns may increase the startup time, When the operating altitude is above 2000 meters, the operating environment temperature needs to be reduced by 5 ℃/1000 meters |